Description
The universal meter YT-73080 with a manual range for each measurement allows for basic and advanced electrical measurements. It is a basic model in our offering. An additional protection against mechanical damage is the so-called holster - a rubber casing that fits over the device's housing.
Basic measurements:
- AC voltage measurement: A.C. 0-600 V
- DC voltage measurement: D.C. 0-600 V
- DC current measurement: D.C. 0-10 A
- Resistance measurement: 0-2 MΩ
- Diode test: IF 1 mA, UR 3 V
- Continuity test: 0-30 Ω
Additional measurements:
- Transistor hFe test: 0-1000
- Square wave generator: 5 Vpp, 50 Hz
Measurement accuracy:
An example of determining accuracy for AC voltage measurement. Calculations for measurement result: 235 V
- The accuracy of the YT-73080 meter for this range is: ±(2% + 10), resolution 1 V
- Error calculation formula: (measurement result x 2%) + 10 x resolution
- Calculations: (235 x 2%) + 10 x 1 = 4.7 + 10 = 14.7 V
The result considering the measurement error for the reading of 235 V = 235 ± 14.7 V*
- The result considering the measurement error for the DC voltage reading: 12 V = 12 ± 0.146 V
A table with resolution and accuracy for a given measurement can be found in the user manual.
*The YT-73080 meter does not have true RMS measurement capability, therefore the above result is the actual effective value of AC voltage only for a proper sinusoidal waveform.
Built-in functions:
- Wave generator - setting the dial to generate a signal will cause the meter to generate a square wave with a peak-to-peak voltage of 5 Vpp at a frequency of approximately 50 Hz. The signal can be used in audio techniques, e.g., in speaker diagnostics.
- DATA HOLD [H] - holds the currently measured value on the display.
Additional information:
- LCD display, maximum displayed result: 1999
- Audible signal in the continuity test for resistance below 30 Ω
- Automatic switching from diode test to continuity test at circuit resistance below 30 Ω (the meter cannot be set only for diode testing)
- Measurement probes included
- Design with overload protection
- ABS plastic housing + the so-called holster, a rubber casing that protects the meter from mechanical damage
- Low battery indicator
- Power supply: 2 x AAA battery
Note!
When measuring unknown values using a meter with manual range adjustment via a dial, measurements should be performed sequentially from the largest range down to the range that provides the most accurate result - otherwise, there is a risk of damaging the device.
| ◀ Article | Parameters | In stock | Price: | ▶ | |
|---|---|---|---|---|---|
| YT-73080 | Alternating voltage : 0-600 V a.c., Direct voltage: 0-600 V d.c., Direct current: 0-10 A, Resistance: 0-2 Mω, HFE transistor test: Pnp|Npn, Continuity test: 0-30 Ω, Conduction test: yes, Diode test: yes, Rectangular signal generator: 50 Hz, Dimensions: 126x70x26 mm, Material: Abs, Display type: Lcd, Display range: 1999 mm, Sampling frequency: 2-3 times per second, Bell ring: yes, Sine wave generator: 5 V p-p, Power supply: battery, Battery type: 2x1.5V, Aaa, Working temperature range: 0~40 ˚C, Storage temperature: -10 ~ +50 ˚C, Weight: 0.14 kg, Application: electric, 14 × 11 × 5 cm, 0.209 kg | Available | 7.25 EUR | Request |